How to control aux heater?: Unterschied zwischen den Versionen

Aus I-BUS App Wiki
Wechseln zu: Navigation, Suche
K (Auxiliary heater in the E46/E83 or auxiliary heater without BUS control)
K
 
(3 dazwischenliegende Versionen desselben Benutzers werden nicht angezeigt)
Zeile 1: Zeile 1:
<br />
 
- side under construction -
 
<br />
 
<br />
 
Check German Version: [[Wie kann ich die Standheizung steuern?]]
 
<br />
 
 
<br />
 
<br />
 
== Control by I-BUS app ==
 
== Control by I-BUS app ==
Zeile 110: Zeile 104:
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
| '''Relais'''|| Bei E46/E83/E85 erfolgt die Ansteuerung der Standheizung via +12V Schaltsignal statt über das BUS System.<br />
+
| '''relay'''|| In the E46/E83/E85 the auxiliary heating is controlled via +12V switching signal instead of via the BUS system.<br />
Mit '''Nachrüstung eines Relais''' (nicht enthalten) kann ein Relais via Massesignal an der grünen Litze vom Resler Modul geschaltet werden.<br />
+
With '''retrofitting a relay''' (not included) a relay may be switched via ground signal on the green wire from the Resler module.<br />
'''WICHTIG! Es wird ein 12V Relais mit mehr als 250 Ohm Erregerwicklung und Freilaufdiode benötigt! Anderenfalls kann das Modul zerstört werden.'''
+
'''IMPORTANT! A 12V relay with more than 250 Ohm excitation winding and recovery diode is required! Otherwise the Resler Module may be destroyed.'''
 
|}<br />
 
|}<br />
 
<br />
 
<br />
Zeile 118: Zeile 112:
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
| '''Funktionstyp'''|| Der Typ kann auf Standheizung/-lüftung oder Relais gesetzt werden.<br />
+
| '''Functional type'''|| The type can be set to auxiliary heating/ventilation or relay.<br />
 
The climate control unit will decide whether to ventilate or heat based on the outside temperature (16°C is the switchover point).
 
The climate control unit will decide whether to ventilate or heat based on the outside temperature (16°C is the switchover point).
 
|}<br />
 
|}<br />
 
<br />
 
<br />
'''This implementation has only been done experimentally so far. If you have any questions, please contact us BEFORE the implementation!'''
+
'''This implementation has only been done experimentally so far. If you have any questions, please contact us BEFORE the implementation!'''<br />
 +
<br />
  
== Voraussetzungen für die Ansteuerung der Standheizung ==
+
== Requirements for the control of the auxiliary heating ==
 
<br />
 
<br />
Die Voraussetzung für die Nutzung der Standheizung ist natürlich, dass eine Standheizung im Wagen verbaut ist, welche '''über das BUS System des Fahrzeuges gesteuert''' wird.<br />
+
The requirement for using the auxiliary heater is of course that an auxiliary heater is installed in the car which is '''controlled via the vehicle's BUS system'''.<br />
Das ist bei allen '''BMW E38/E39/E53''' mit Standheizung ab Werk der Fall.<br />
+
This is the case with all '''BMW E38/E39/E53''' with auxiliary heater ex works.<br />
Dazu haben alle Dieselmotoren (M47/M57) einen sogenannten "Zuheizer", der baugleich mit der Standheizung ist. Es fehlt nur die passende Codierung und eigentlich ein Umschaltventil (wo mit NUR der Motor geheizt wird).<br />
+
All diesel engines (M47/M57) have a so-called " additional heater", which is identical in construction to the auxiliary heater. The only thing missing is the appropriate coding and actually a switching valve (where ONLY the passenger compartment is heated).<br />
Standheizung ab Werk heizt also nur den Kühlkreislauf für die Fahrgastzelle - nicht den Motor.<br />
+
The factory-fitted auxiliary heater thus only heats the cooling circuit for the passenger compartment - not the engine.<br />
Ein zur Standheizung codierter Zuheizer (oder eine Standheizung mit abgestecktem Umschaltventil) heizt den kleinen Kühlkreislauf und erwärmt somit Motor und die Fahrgastzelle.<br />
+
An additional heater coded to an auxiliary heater (or an auxiliary heater with a disconnected changeover valve) heats the small cooling circuit and thus heats the engine and the passenger compartment.<br />
Dazu findet man auch im Motorraum auf dem rechten Dom einen weißen Sticker der Firma "Webasto". Dieser besagt erstmal nur, dass eine Webasto Thermotop C/Z verbaut ist. Nicht aber, ob es eine Standheizung oder nur ein Zuheizer ist.<br /><br />
+
There is also a white "Webasto" sticker in the engine compartment on the right-hand dome. This only says that a Webasto Thermotop C/Z is installed. But it does not say whether it is a auxiliary heater or only an additional heater.<br /><br />
Der Einfachheit halber werden wir "Standheizung" mit "STH" und "Standlüftung" mit "STL" abkürzen.
+
For the sake of simplicity, we will abbreviate " auxiliary heating" with "aux heat" and "auxiliary ventilation" with "aux vent".
 
<br /><br />
 
<br /><br />
<font color="red"><big>'''HINWEIS: wird bei Fahrzeugen OHNE Standheizung die Funktion auf Standheizung gesetzt und diese gestartet, so kommt es zu Fehlfunktionen. Oft wird das Gebläse gestartet und kann nur durch Abklemmen der Fahrzeugbatterie gestoppt werden!!! Stellen Sie daher sicher ob eine Standheizung verbaut ist.'''</big> </font> <br />
+
<font color="red"><big>'''NOTE: If the function is set to auxiliary heating on vehicles WITHOUT auxiliary heating and this is started, malfunctions will occur. Often the fan is started and can only be stopped by disconnecting the vehicle battery. Therefore, make sure that a auxiliary heating is present.'''</big> </font> <br />
<font color="red"><big>Ein Indiz auf eine verbaute Standheizung kann(!) einen Aufkleber der Firma "Webasto" im Motorraum auf dem Dom links sein. Allerdings ist dieser auch vorhanden, wenn bei Dieselfahrzeugen nur ein Zuheizer codiert ist.</big> </font>
+
<font color="red"><big>A sticker of the company "Webasto" in the engine compartment on the right-hand side of the dome can(!) be an indication of an installed auxiliary heater. However, this is also present if only an additional heater is coded in the case of diesel vehicles.</big> </font>
 
<br /><br />
 
<br /><br />
=== Steuerung ab Werk ===
+
=== Control ex works ===
 
<br />
 
<br />
Um sicher zu sein, dass das "Webasto-Gerät" auch als Standheizung funktioniert kann man z.B. im Original-Menü vom MID oder Bordmonitor nachsehen.<br />
+
To be sure that the "Webasto device" also functions as a auxiliary heater, you might want to check the original menu of the MID or the on-board monitor.<br />
Hier sollte man neben der "Standlüftung" (welche mit elektronischem Klimabedienteil immer verfügbar ist) auch "Standheizung" aufgeführt und ansteuerbar sein.<br />
+
In addition to " auxiliary ventilation" (which is always available with the electronic climate control unit), "auxiliary heating" should also be listed and controllable.<br />
Im MID findet man dazu die Option "HEIZ EIN" und "LÜFT EIN", nachdem man auf das Uhr Icon gedrückt hat.
+
In the MID, you will find the option "HEAT" and "VENT" after pressing the clock icon.<br />
Sollte hier nur die Standlüftung aufgeführt sein, so wird es zu Fehlfunktionen kommen, wenn man versucht die STH via App/Modul anzusteuern!!!<br />
+
If only the auxiliary ventilation is listed here, malfunctions will occur if you try to control the aux heater via the app/module.<br />
'''Daher bitte unbedingt vorher sicherstellen, dass die STH auch als solche codiert ist!'''<br />
+
'''Therefore, please make sure beforehand that the aux heater is also coded as such!'''<br />
 
<br />
 
<br />
=== Timer: Standheizen oder -lüften? ===
+
=== Timer: auxiliary heater or ventilator? ===
 
<br />
 
<br />
Die Entscheidung ob beim Erreichen des Timers geheizt oder gelüftet wird trifft das Klimabedienteil auf Basis der Außentemperatur.<br />
+
The decision whether to heat or ventilate when the timer is activated is made by the climate control unit on the basis of the outside temperature.<br />
Hierzu ist es essentiell, dass der Sensor intakt ist und plausible Werte im Tacho gezeigt werden. Bei defektem Sensor wird im Tacho permanent "-40°C" gezeigt, entsprechend startet IMMER die STH, egal welche Außentemperatur tatsächlich anliegt.<br />
+
For this it is essential that the sensor is intact and plausible values are shown in the speedometer. If the sensor is defective, the speedometer will permanently show "-40°C" and the aux heater will ALWAYS start, regardless of the actual outside temperature.<br />
 
<br />
 
<br />
=== Abbruchkriterien ===
+
=== Abandonment criteria===
 
<br />
 
<br />
Die STH wird abgeschaltet, wenn:
+
The STH will be switched off if:
* die Kühlmitteltemperatur 70°C übersteigt
+
* the coolant temperature exceeds 70°C
* die Spannung unter 10V fällt
+
* the voltage drops below 10V
 
* der Tankinhalt unter 7l fällt
 
* der Tankinhalt unter 7l fällt
* die Laufzeit 30min erreicht hat
+
* the running time has reached 30min
* ein Defekt der Standheizung vorliegt<br />
+
* there is a defect in the auxiliary heating<br />
 
<br />
 
<br />

Aktuelle Version vom 7. Dezember 2022, 07:56 Uhr


Control by I-BUS app


If it is ensured that the aux heater was installed and can be controlled with the original radio/navi, the "Parking heater" option can be activated in the other settings of the I-BUS app.

Control with former navigation system ex works


Make sure that the option "emulate MID requests" is NOT activated and the option "aux heating" is activated.

The " auxiliary heating" entry then also appears on the "Control" tab and the " auxiliary ventilation" entry. Both can be started directly via the slider next to it.
Above are two timers for which a start time can be set.
If the timer is set successfully, you can call up the respective start time in the speedometer with large text display (provided the PROG function "TIME1" and "TIME2" are active), which is marked with an star.
The timer is now successfully set. The speedometer takes over the start of the aux heater/ventilation at the set time.



Control with former radio only ex works


Make sure that the option "emulate MID requests" and the option "auxiliary heating" are activated.

On the "Control" page, a large "MID" button appears. After pressing this button, an emulated MID appears, as it was known before. Click on "Clock" to access the menu for setting "TIMER1" or "TIMER2". After the start time has been successfully set, a star is placed in front of "TIMER1"/"TIMER2".


Control by orange Resler Module


The auxiliary heating can be controlled separately from the I-BUS app or with the app with the orange Resler module.
This means even with a radio/navigation system ex works or a third-party radio without Android you can use the aux heater/ventilation via the module with the remote control in the vehicle key (within its range).
Optionally you can also set up to ten timers and thus program a week in advance or repeatedly. This is also possible via an Android smartphone, which is only temporarily plugged in for the purpose of programming and uses the I-BUS app for this (even without a licence!).

The Resler module can perform the control of the auxiliary heating/ventilation.
Initially the type must be defined (especially for control via remote control).

OFF There is NO control of the auxiliary heating/ventilation.
type 1 Only for E38/E39/E53 with high BC speedometer
type 2 E38/E39/E53 with Low BC speedometer
relay In the E46/E83/E85 the auxiliary heating is controlled via +12V switching signal instead of via the BUS system.

With retrofitting a relay (not included) a relay may be switched via ground signal on the green wire from the Resler module.
IMPORTANT! A 12V relay with more than 250 Ohm excitation winding and recovery diode is required! Otherwise the Resler Module may be destroyed.

To decide which type to set, please check: Habe ich High oder Low BC?

Direct start of the auxiliary heating/ventilation via remote control

The remote control in the vehicle key can be used to start/stop the auxiliary heating/ventilation directly.
Use the slider to determine whether the auxiliary heating or auxiliary ventilation is to be used.

Starting auxiliary heating/ventilation The vehicle has to be locked. Press and hold the close button on the key for approximately 2 seconds. The start is confirmed visually by 2x "slow flashing".
Stop auxiliary heating/ventilation The vehicle has to be locked and the auxiliary heating/ventilation has to be running. Press and hold the close button on the key for approx. 2 seconds. The stop is confirmed visually by 3x "slow flashing". Note: The auxiliary heating cools down with the combustion air fan for approx. 180s so that it does not stop immediately.



Timer control for auxiliary heating/ventilation

The Resler Module allows pre-programming of up to 8 timers with a lead time of up to one week and weekly repetition beyond that.

Example Example
activate/ deactivate timer Set the slider accordingly. After the timer has run, it is deactivated.
Start time Set the start time for the timer
Duration Setting the duration of the timer (1-30 minutes)
Days Set the days on which the timer should be active
Weekly repetition The complete timer is repeated continuously every week as it is set.

The option also has to be set if the timer shall run on more than one day. Otherwise the timer will be deactivated after the first run.

Functional type The type can be set to auxiliary heating/ventilation or relay.

The air-conditioning control unit decides whether ventilation or heating is required based on the outside temperature (16°C is the switchover point).

NOTE: Since the air conditioning control unit decides which function is to be implemented the timer can usually always be used for the auxiliary ventilation function (except E46/E83/E85) even if no auxiliary heating is installed.



Auxiliary heater in the E46/E83 or auxiliary heater without BUS control


Auxiliary heaters which are not controlled via the vehicle BUS but only via a 12V control signal cannot be controlled via the I-BUS app.
However, there is the option to use the ground switching output (green wire) as well as a suitable relay circuit (miniature relay plus free-wheeling diode!!!!) and to set the module properly.
It is absolutely essential to use only a small relay (not a car relay! - max. 100mA load!!! / at least 250 ohms exciter coil ) with a free-wheeling diode to switch the ground contact on the relay. The supply with permanent positive at the relay and for switching through to the aux heater must be separately arranged and fused! If this is not observed, the module may be damaged irreparably!

Einstellung für Direktstart via FFB muss auf "Relais" gesetzt werden:

relay In the E46/E83/E85 the auxiliary heating is controlled via +12V switching signal instead of via the BUS system.

With retrofitting a relay (not included) a relay may be switched via ground signal on the green wire from the Resler module.
IMPORTANT! A 12V relay with more than 250 Ohm excitation winding and recovery diode is required! Otherwise the Resler Module may be destroyed.



If the timer is used, the function type must also be set to "relay":

Functional type The type can be set to auxiliary heating/ventilation or relay.

The climate control unit will decide whether to ventilate or heat based on the outside temperature (16°C is the switchover point).



This implementation has only been done experimentally so far. If you have any questions, please contact us BEFORE the implementation!

Requirements for the control of the auxiliary heating


The requirement for using the auxiliary heater is of course that an auxiliary heater is installed in the car which is controlled via the vehicle's BUS system.
This is the case with all BMW E38/E39/E53 with auxiliary heater ex works.
All diesel engines (M47/M57) have a so-called " additional heater", which is identical in construction to the auxiliary heater. The only thing missing is the appropriate coding and actually a switching valve (where ONLY the passenger compartment is heated).
The factory-fitted auxiliary heater thus only heats the cooling circuit for the passenger compartment - not the engine.
An additional heater coded to an auxiliary heater (or an auxiliary heater with a disconnected changeover valve) heats the small cooling circuit and thus heats the engine and the passenger compartment.
There is also a white "Webasto" sticker in the engine compartment on the right-hand dome. This only says that a Webasto Thermotop C/Z is installed. But it does not say whether it is a auxiliary heater or only an additional heater.

For the sake of simplicity, we will abbreviate " auxiliary heating" with "aux heat" and "auxiliary ventilation" with "aux vent".

NOTE: If the function is set to auxiliary heating on vehicles WITHOUT auxiliary heating and this is started, malfunctions will occur. Often the fan is started and can only be stopped by disconnecting the vehicle battery. Therefore, make sure that a auxiliary heating is present.
A sticker of the company "Webasto" in the engine compartment on the right-hand side of the dome can(!) be an indication of an installed auxiliary heater. However, this is also present if only an additional heater is coded in the case of diesel vehicles.

Control ex works


To be sure that the "Webasto device" also functions as a auxiliary heater, you might want to check the original menu of the MID or the on-board monitor.
In addition to " auxiliary ventilation" (which is always available with the electronic climate control unit), "auxiliary heating" should also be listed and controllable.
In the MID, you will find the option "HEAT" and "VENT" after pressing the clock icon.
If only the auxiliary ventilation is listed here, malfunctions will occur if you try to control the aux heater via the app/module.
Therefore, please make sure beforehand that the aux heater is also coded as such!

Timer: auxiliary heater or ventilator?


The decision whether to heat or ventilate when the timer is activated is made by the climate control unit on the basis of the outside temperature.
For this it is essential that the sensor is intact and plausible values are shown in the speedometer. If the sensor is defective, the speedometer will permanently show "-40°C" and the aux heater will ALWAYS start, regardless of the actual outside temperature.

Abandonment criteria


The STH will be switched off if:

  • the coolant temperature exceeds 70°C
  • the voltage drops below 10V
  • der Tankinhalt unter 7l fällt
  • the running time has reached 30min
  • there is a defect in the auxiliary heating