Resler Module Settings: Unterschied zwischen den Versionen

Aus I-BUS App Wiki
Wechseln zu: Navigation, Suche
K (Lichtsteuerung)
K (Standheizung/Standlüftung)
Zeile 148: Zeile 148:
 
----
 
----
  
== Standheizung/Standlüftung ==
+
== Auxiliary heating/ventilation ==
<font color="red"><big>'''HINWEIS: wird bei Fahrzeugen OHNE Standheizung die Funktion auf Standheizung gesetzt und diese gestartet, so kommt es zu Fehlfunktionen. Oft wird das Gebläse gestartet und kann nur durch Abklemmen der Fahrzeugbatterie gestoppt werden!!! Stellen Sie daher sicher ob eine Standheizung verbaut ist.'''</big> </font> <br />
+
<font color="red"><big>'''NOTE: If the function is set to auxiliary heating on vehicles WITHOUT auxiliary heating and this is started, malfunctions will occur. Often the fan is started and cannot be stopped unless the vehicle battery is disconnected. Therefore make sure that a auxiliary heating is installed.'''</big> </font> <br />
<font color="red"><big>Ein Indiz auf eine verbaute Standheizung kann(!) einen Aufkleber der Firma "Webasto" im Motorraum auf dem Dom links sein. Allerdings ist dieser auch vorhanden, wenn bei Dieselfahrzeugen nur ein Zuheizer codiert ist.</big> </font>
+
<font color="red"><big>An indication of an installed auxiliary heater can(!) be a sticker of the manufacturer "Webasto" in the engine compartment on the left dome. However this is also present if only one auxiliary heater is coded on diesel vehicles.</big> </font>
 
<gallery mode="packed-hover">
 
<gallery mode="packed-hover">
RM STH 00.jpg|Einstellungen Standheizung/Standlüftung
+
RM STH 00.jpg|settings auxiliary heating/ventilation
RM STH 01.jpg|Typ Standheizung/Standlüftung
+
RM STH 01.jpg|types of auxiliary heating/ventilation
 
</gallery>
 
</gallery>
Das Resler Modul kann die Ansteuerung der Standheizung/Standlüftung umsetzen.<br />
+
The Resler module can perform the control of the auxiliary heating/ventilation.<br />
Initial muss hierzu der Typ festgelegt werden (insbesondere für die Steuerung via Fernbedienung).
+
Initially the type must be defined (especially for control via remote control).
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
| '''Aus'''|| Es erfolgt KEINE Ansteuerung von Standheizung/Standlüftung
+
| '''OFF'''|| There is NO control of the auxiliary heating/ventilation.
 
|-
 
|-
| '''Typ 1'''|| Nur für E38/E39/E53 mit High BC Tacho
+
| '''type 1'''|| Only for E38/E39/E53 with high BC speeedometer
 
|-
 
|-
| '''Typ 2'''|| E38/E39/E53 mit Low BC Tacho
+
| '''type 2'''|| E38/E39/E53 with Low BC speeedometer
 
|-
 
|-
| '''Relais'''|| Bei E46/E83/E85 erfolgt die Ansteuerung der Standheizung via +12V Schaltsignal statt über das BUS System.<br />
+
| '''relay'''|| In the E46/E83/E85 the auxiliary heating is controlled via +12V switching signal instead of via the BUS system.<br />
Mit '''Nachrüstung eines Relais''' (nicht enthalten) kann ein Relais via Massesignal an der grünen Litze vom Resler Modul geschaltet werden.<br />
+
With '''retrofitting a relay''' (not included) a relay may be switched via ground signal on the green wire from the Resler module.<br />
'''WICHTIG! Es wird ein 12V Relais mit mehr als 250 Ohm Erregerwicklung und Freilaufdiode benötigt! Anderenfalls kann das Modul zerstört werden.'''
+
'''IMPORTANT! A 12V relay with more than 250 Ohm excitation winding and recovery diode is required! Otherwise the Resler Module may be destroyed.'''
 
|}
 
|}
Für die Entscheidung welcher Typ gesetzt werden muss bitte prüfen: [[Habe ich High oder Low BC?]]<br />
+
To decide which type to set, please check: [[Habe ich High oder Low BC?]]<br />
 
<br />
 
<br />
=== Direkt-Start der Standheizung/Standlüftung via Fernbedienung ===
+
=== Direct start of the auxiliary heating/ventilation via remote control ===
Mit der Fernbedienung im Fahrzeugschlüssel kann Standheizung/Standlüftung direkt gestartet/beendet werden.<br />
+
The remote control in the vehicle key can be used to start/stop the auxiliary heating/ventilation directly.<br />
Dazu mit dem Schieberegler festlegen, ob Standheizung oder Standlüftung genutzt werden soll.<br />
+
Use the slider to determine whether the auxiliary heating or auxiliary ventilation is to be used.<br />
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
| '''Start der Standheizung/Standlüftung'''|| Das Fahrzeug muss verriegelt sein. Schließen-Taste auf dem Schlüssel für ca. 2s Drücken und halten. Der Start wird durch '''2x "langsam Blinken"''' optisch bestätigt.
+
| '''Starting auxiliary heating/ventilation'''|| The vehicle has to be locked. Press and hold the close button on the key for approximately 2 seconds. The start is confirmed visually by '''2x "slow flashing"'''.
 
|-
 
|-
| '''Stopp der Standheizung/Standlüftung'''|| Das Fahrzeug muss verriegelt sein und die Standheizung/Standlüftung laufen. Schließen-Taste auf dem Schlüssel für ca. 2s Drücken und halten. Der Stopp wird durch '''3x "langsam Blinken"''' optisch bestätigt. Hinweis: Die Standheizung kühlt mit dem Brennluftgebläse ca. 180s nach, so dass sie nicht sofort verstummt.
+
| '''Stop auxiliary heating/ventilation'''|| The vehicle has to be locked and the auxiliary heating/ventilation has to be running. Press and hold the close button on the key for approx. 2 seconds. The stop is confirmed visually by '''3x "slow flashing"'''. Note: The auxiliary heating cools down with the combustion air fan for approx. 180s so that it does not stop immediately.
 
|}
 
|}
 
<br /><br />
 
<br /><br />
  
=== Timer-Steuerung für Standheizung/Standlüftung ===
+
=== Timer control for auxiliary heating/ventilation ===
Das Modul erlaubt eine Vorprogrammierung von bis zu 8 Timern mit einem einem Vorlauf von bis zu einer Woche und darüber hinaus wöchentlicher Wiederholung.<br />
+
The Resler Module allows pre-programming of up to 8 timers with a lead time of up to one week and weekly repetition beyond that.<br />
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
| Beispiel || Beispiel
+
| Example|| Example
 
|-
 
|-
| '''Timer aktivieren/ deaktivieren'''|| Setze den Slider entsprechend. Nach dem der Timer gelaufen ist, wird er deaktiviert.
+
| '''activate/ deactivate timer'''|| Set the slider accordingly. After the timer has run, it is deactivated.
 
|-
 
|-
| '''Startzeit'''|| Setzen der Startzeit für den Timer
+
| '''Start time'''|| Set the start time for the timer
 
|-
 
|-
| '''Dauer'''|| Setzen der Laufdauer des Timers (1-30 Minuten)
+
| '''Duration'''|| Setting the duration of the timer (1-30 minutes)
 
|-
 
|-
| '''Tage'''|| Setze die Tage, an denen der Timer aktiv sein soll
+
| '''Days'''|| Set the days on which the timer should be active
 
|-
 
|-
| '''Wöchentliche Wiederholung'''|| Der Komplette Timer wird so wie er gesetzt ist jede Woche fortlaufend wiederholt.<br />
+
| '''Weekly repetition'''|| The complete timer is repeated continuously every week as it is set.<br />
Die Option muss auch gesetzt werden, wenn der Timer an mehr als einem Tag laufen soll, anderenfalls wird der Timer nach dem ersten Lauf deaktiviert.
+
The option also has to be set if the timer shall run on more than one day. Otherwise the timer will be deactivated after the first run.
 
|-
 
|-
| '''Funktionstyp'''|| Der Typ kann auf Standheizung/-lüftung oder Relais gesetzt werden.<br />
+
| '''Functional type'''|| The type can be set to auxiliary heating/ventilation or relay.<br />
Ob gelüftet oder geheizt wird entscheidet das Klimabedienteil anhand der Außentemperatur (16°C ist der Umschaltpuntk).
+
The air-conditioning control unit decides whether ventilation or heating is required based on the outside temperature (16°C is the switchover point).
 
|}
 
|}
'''HINWEIS''': Da das Klimabedienteil die Entscheidung trifft welche Funktion umgesetzt wird kann der Timer in der Regel immer für die Funktion des Standlüftens (außer E46/E83/E85) genutzt werden, auch wenn keine Standheizung verbaut ist.</big>
+
<big>'''NOTE''': Since the air conditioning control unit decides which function is to be implemented the timer can usually always be used for the auxiliary ventilation function (except E46/E83/E85) even if no auxiliary heating is installed.</big>
 
<gallery mode="packed-hover">
 
<gallery mode="packed-hover">
RM STH 02.jpg|Standheizung/Standlüftung - Timerübersicht
+
RM STH 02.jpg|Auxiliary heating/ventilation - timer overview
RM STH 03.jpg|Standheizung/Standlüftung -Timer-Einstellung
+
RM STH 03.jpg|Auxiliary heating/ventilation - timer settings
 
</gallery>
 
</gallery>
 
<br /><br />
 
<br /><br />

Version vom 20. Juli 2022, 19:19 Uhr

Main menu


All Resler Module settings occur when a Resler Module was plugged and I-BUS app have been reactivated.
They are located at the second position in the I-BUS App settings and are subdivided into the topics:



General note: The module is only able to implement functions for installed and intact features of the car. (e.g. folding mirrors up/down only works if the mirrors have this function and it is intact - usually this function is also available without the module via other controls).


Mirror control

  • Mirror folding/unfolding: Sets the start conditions for the folding/unfolding of the mirrors. The following options are available:
    • Off
    • Double-tapping the remote control
    • always active
  • invert unfold mirror: If the mirrors fold in when unlocking, the function can be inverted here
  • Unfolding the mirrors when the ignition is turned on: Unfolding of the (folded) mirrors only happens when the ignition level 2 is engaged.




Coming/Leaving Home

Here you find the following functions:

Coming Home [CH] ("Home lights" - Lights up e.g. when locking the car)
Leaving Home [LH] ("Welcome lights" - Lights up e.g. when unlocking the car)


We shorten both functions with "CHLH".

Starting time for CHLH

CHLH may be always on oder always off .
or
set start and end manually. Only if so underneath following items are shown:

Coming Home end time Time of day until CHLH is active1
Coming Home start time Time of day from which on CHLH is active1

or
Automatically calculate the start/end time based on location, date and twilight type:

Daytime calculation mode2 Sets the start/end time depending on the GPS position, date and twilight process (sunrise/sunset) when turn ignition off
CHLH start time delay Sets time difference "xx" before sunset/time of day calculation when CHLH should start
(Window: -120 ... +120 minutes, negative time moves the time forward, positive moves it backwards).
CHLH end time delay Sets time difference "yy" after sunset/time of day calculation when CHLH should end
(Window: -120 ... +120 minutes, negative time moves the time forward, positive moves it backwards).

1unless "always active" or a "time of day calculation mode" is set
2 Calculation options see table, calculated time incl. displacement is displayed in the status

Computation model Explanation
No calculation of the day times Use of fixed times, always active or always off
Sunrise/sunset Calculated sunrise and sunset
Civil twilight Darkness beyond which it is no longer possible to work or read outside without artificial light.
Nautical twilight Follow the civil twilight to the darkness beyond which you cannot yet see the stars.
Astronomical twilight From this level of darkness, stars are visible in the sky


Additional start/stop signals for CHLH

In addition the following start/stop signals for CHLH can be defined:

CHLH Start/stop by ignition Coming Home sequence begins with ignition off. Leaving Home sequence ends with ignition on (if it is still running).
Coming Home start when opening a door Coming Home sequence already starts with opening a door after switching off the ignition
Leaving Home stop when opening a door Stop the Leaving Home sequence with opening a door, if it is still running.
Activate CHLH in underground car park If this option is activated, CHLH is activated if the GPS signal is lost (takes about 60 seconds), e.g. in an underground car park. This means that the lights also start outside the set time if the GPS signal is missing.

These functions are partly locked against each other so that they are mutually exclusive.

Light sequences for Coming Home/Leaving Home

The Resler Module has a microcontroller and a clock module so that it is possible to create light sequences for CHLH as desired.
A total of up to 100 sequences are possible, which can be divided between CH and LH as desired. Setting the light sequence is done as already known via the menu light control

Quick guide:
After creating/loading/importing the light sequence:

  1. Tap on „Save“
  2. e.g. select memory slot 2 - 6 (memory slot 1 is intended in the app for "2x headlight flasher, not for CHLH).
  3. Confirm question for use as Coming/Leaving Home
  4. Select use for Coming OR Leaving Home
  5. Confirm "Send to Resler Module"
  6. Wait for successful writing to the Resler module, if an error occurs, restart at 1).

Download and insert sample light sequences for Coming Home/Leaving Home

In Load', there is now also the Import from the Resler module or from the memory of the radio (e.g. with sequences created on the PC or example sequences).


Light control

In the light control it is generally possible to switch whether the functions are to be performed by the Resler module or I-BUS app.
The advantage of control via the Resler module is that it works independently of the I-BUS App and radio. This means that the functions are available even when the radio is switched off or the I-BUS app is closed.
Otherwise these functions correspond to those of the app.
To "switch off" the daytime running lights simply deselect all lights.


Auxiliary heating/ventilation

NOTE: If the function is set to auxiliary heating on vehicles WITHOUT auxiliary heating and this is started, malfunctions will occur. Often the fan is started and cannot be stopped unless the vehicle battery is disconnected. Therefore make sure that a auxiliary heating is installed.
An indication of an installed auxiliary heater can(!) be a sticker of the manufacturer "Webasto" in the engine compartment on the left dome. However this is also present if only one auxiliary heater is coded on diesel vehicles.

The Resler module can perform the control of the auxiliary heating/ventilation.
Initially the type must be defined (especially for control via remote control).

OFF There is NO control of the auxiliary heating/ventilation.
type 1 Only for E38/E39/E53 with high BC speeedometer
type 2 E38/E39/E53 with Low BC speeedometer
relay In the E46/E83/E85 the auxiliary heating is controlled via +12V switching signal instead of via the BUS system.

With retrofitting a relay (not included) a relay may be switched via ground signal on the green wire from the Resler module.
IMPORTANT! A 12V relay with more than 250 Ohm excitation winding and recovery diode is required! Otherwise the Resler Module may be destroyed.

To decide which type to set, please check: Habe ich High oder Low BC?

Direct start of the auxiliary heating/ventilation via remote control

The remote control in the vehicle key can be used to start/stop the auxiliary heating/ventilation directly.
Use the slider to determine whether the auxiliary heating or auxiliary ventilation is to be used.

Starting auxiliary heating/ventilation The vehicle has to be locked. Press and hold the close button on the key for approximately 2 seconds. The start is confirmed visually by 2x "slow flashing".
Stop auxiliary heating/ventilation The vehicle has to be locked and the auxiliary heating/ventilation has to be running. Press and hold the close button on the key for approx. 2 seconds. The stop is confirmed visually by 3x "slow flashing". Note: The auxiliary heating cools down with the combustion air fan for approx. 180s so that it does not stop immediately.



Timer control for auxiliary heating/ventilation

The Resler Module allows pre-programming of up to 8 timers with a lead time of up to one week and weekly repetition beyond that.

Example Example
activate/ deactivate timer Set the slider accordingly. After the timer has run, it is deactivated.
Start time Set the start time for the timer
Duration Setting the duration of the timer (1-30 minutes)
Days Set the days on which the timer should be active
Weekly repetition The complete timer is repeated continuously every week as it is set.

The option also has to be set if the timer shall run on more than one day. Otherwise the timer will be deactivated after the first run.

Functional type The type can be set to auxiliary heating/ventilation or relay.

The air-conditioning control unit decides whether ventilation or heating is required based on the outside temperature (16°C is the switchover point).

NOTE: Since the air conditioning control unit decides which function is to be implemented the timer can usually always be used for the auxiliary ventilation function (except E46/E83/E85) even if no auxiliary heating is installed.




Baureihe ändern


Zusätzlich zur korrekt gesetzten Baureihe in den den allgemeinen Einstellungen der I-BUS App bitte prüfen, ob die Baureihe des Fahrzeuges in den Resler Modul Einstellungen zum Fahrzeugtyp passt!
Das ist essentiell für eine korrekte Funktion.
Ist die falsche Baureihe gewählt, kann es zu Fehlfunktionen kommen!


Altes GM-Modul


Wenige ältere E38 und E39 (vermutlich vor Baujahr 1995) haben ein "altes Grundmodul" (GM) verbaut. Sollte das genutzte Fahrzeug in diesem Zeitraum gefertigt worden sein UND keine Funktionen via Funkfernbedienung funktionieren (normal Ver-/Entriegeln muss unabhängig vom Resler Modul funktionieren!), so kann diese Option aktiviert werden um das "CHLH via Fernbedienung" und "Spiegelklappen via Fernbedienung" nutzen zu können.
Die Funktionen für 2x oder lange Drücken der Fernbedienung (z.B. Standheizung/-lüftung via FFB Starten) entfallen bislang hierbei. Spiegel werden immer an-/abgeklappt.


Modul-Modus


Im Modul-Modus kann man wählen, ob:

  • alle Funktionen aktiv sind
  • alle Funktionen des Moduls bei angeschaltener Zündung deaktiviert werden (so bleiben: Coming/Leaving Home und Spiegel an-/abklappen)
  • alle Funktionen des Moduls DEAKTIVIERT sind




Resler Modul Status

Im „Resler Modul Status“ findet ihr wichtige Informationen wie zum Beispiel:

  • Die Zeit im Resler Modul und dem Radio (Android-System-Zeit)
  • Die Seriennummer vom Resler Modul (wird registriert)
  • Die Firmware-Version vom Resler Modul
  • I-BUS Status: zeigt ob alle Anschlüsse am Modul i.O. sind oder ob etwas fehlt (BUS-Signal, 12V, Masse)
  • Einige Zähler, die ggf. für uns relevant sein können


Dazu befinden sich unten einige Buttons mit folgenden Funktionen:

Button Funktion bei kurzem Tippen Funktion bei langem Tippen
Status Lädt die Status Informationen neu Setz den Status und die Zähler zurück
CH/LH Zeigt die Start- und Endzeit für CH/LH Zeigt die Lichtfolgen für CH/LH (nur als Kurz-Code)
CH/LH EIN/AUS CH/LH immer an oder aus schalten Start-/Endzeiten für CH/LH manuell setzen
ZEIT STELLEN Setzt die Android System-Zeit auf das Modul -
EEPROM LÖSCHEN Löscht den Speicher auf dem Modul -
FLASHEN Öffnet das Menü zum Flashen des Resler Moduls (neue Firmware aufspielen) Setzt das Modul zurück



I-BUS Status

Über den I-BUS Status kann der korrekte Anschluss des Resler Moduls geprüft werden.
Folgende Informationen sind verfügbar.

Status Bedeutung Maßnahme
OK Aktivität auf dem I-BUS erkannt. Anschluss ist korrekt -
No activity on IBUS weiße I-BUS Leitung nicht oder auf +12V Leitung angeschlossen Anschluss der weißen Litze prüfen
IBUS Line Permanent grounded weiße I-BUS Leitung auf Masse angeschlossen Anschluss der weißen Litze prüfen
No +12V Power +12 V Anschluss fehlt am roten Kabel Anschluss der roten Litze auf Dauerplus (und braune Litze auf Masse) prüfen und sicherstellen.

Weitere Informationen zum Anschluss siehe: Einbauanleitung für Resler Modul und Resler Interface

Resler Modul manuell flashen

In der Regel wird bei App-Start geprüft ob es eine neue App-Version und/oder Firmware für das Modul verfügbar ist3. Sofern etwas vorliegt wird das Update angeboten und kann direkt ausgeführt werden.

Sollte ein manuelles Flashen notwendig sein:

  1. Resler Modul Einstellungen öffnen
  2. Resler Modul Status öffnen
  3. Tippen auf den Button „Flashen“
  4. Es öffnet sich die Auswahl der verfügbaren Datenträger. Hier den Datenträger wählen auf dem sich die Flashdatei4 befindet und durch die Ordner Struktur zum Speicherort navigieren wo sich die Datei befindet.
  5. Die gewünschte Datei antippen startet den Flash-Vorgang.
  6. Das Flashen abwarten und das Flash-Menü danach verlassen.


Optional kann das Resler Modul auch am PC mit dem Resler Modul Konfigurator geflasht werden.

Neben dem manuellen Flashen gibt es natürlich auch die Option manuell nach von uns freigegebenen Firmware-Updates zu suchen, so wie es auch bei der App funktioniert. Der Button zur manuellen Prüfung ob Updates vorhanden sind befindet sind mit im linken Menü: „Firmware Update“.

3 Aktive Internet-Verbindung vorausgesetzt.
4 freigegebenen Firmware-Updates

Thema: Verbraucherabschaltung


Mit dem neuen Resler Modul wird das Umklemmen des Radios auf die Verbraucherabschaltung NICHT mehr benötigt.
Es ist daher dringend dazu zu raten, das Radio wieder "normal" auf Klemme 15/Zündung anzuklemmen!!!


allgemeine Infos zum Resler Modul

Resler Modul